CTC-1
APPLICATIONS
Crane Scales, Silos and hopper weighing.
Overload protection.
FEATURES
Tension load cell.
3000 divisions OIML R60 Class C.
Hermetically sealed by laser welding.
Fully stainless steel construction.
Protected against humidity IP68 (EN60529).
Description
Nominal capacities 150-300-500-750-1000 kg
Accuracy class 3000
Input impedance 386Ω±2%
Output impedance 350±3Ω
Input voltage range 5..12 V
Nominal sensitivity 2mV/V
Operating temperature range -10 a +50ºC
Service load 150% (N.L.)
Safe load limit > 200 % (N.L.)
Sensitivity tolerance +/- 0.1% (N.L.)
Temperature effect on sensitivity (-10…+40ºC) <+/-0.001%/ºC
Temperature effect on cero (-10…+50ºC) <+/-0.001%/ºC
Maximum combined error: <+/- 0.02 (N.L.)
Creep in 30’ at 20ºC +/- 0.02%
Cable length 5 m
Electrical connection 4 wires